1. Conditions of use
HS-D(S) series electric lubrication pump is suitable for applications with many lubrication points and wide distribution range.Process lubricationIn the single or double-line dry (thin) oil centralized lubrication system with high oil feeding frequency and nominal pressure of 40MPa, as a device for supplying lubricant, it can also be equipped with a mobile trolley, hose, oil gun and cable to form a mobile electric lubricant. The lubrication pump device is used for mobile oiling in single-machine equipment with low oiling frequency, few lubrication points, large oiling volume and inconvenient centralized lubrication. The oil storage barrel is also equipped with an automatic oil level alarm device. If equipped with the corresponding The electrical control box can also realize automatic control and monitor the system.
2. Technical parameters
The medium used is grease (NLGI 0#~3#) with a cone penetration of not less than 220 (25°C, 150g) 1/10mm and lubricating oil with a viscosity grade not less than N68.
3. Model description
4. Overall dimensions
5. Instructions for use
1. The pump should be installed in a place where the ambient temperature is suitable, there is little dust, and it is easy to adjust, inspect, repair, disassemble and clean, and facilitate grease replenishment.
2. Arrange it in the center of the system as much as possible, shorten the piping length, and keep the pressure drop low so that the pump can generate enough energy to overcome the problem.Smart lubricationpoint resistance pressure.
3. Before use, 50# mechanical oil must be filled into the reduction box to the height specified by the oil mark.
4. The set pressure of the pressure regulating valve can be adjusted arbitrarily within the range of 0 to 40MPa. It is not allowed to exceed the nominal pressure of the pump by 40MPa during use.
5. The filter in the collecting valve body should be cleaned regularly to prevent clogging.
6. If the system pressure reaches about 50MPa due to some kind of failure, the fuse will rupture. Find out the cause and install a new fuse after troubleshooting.
7. To replenish grease into the oil reservoir, you must use an electric refueling pump to add it from the grease port of the oil reservoir.
8. This pump is for indoor installation. When used outdoors or in harsh environments, protective measures must be taken.
6. Ordering Notes
1. When ordering H SD(S) series electric lubrication pump with trolley device, the required hose length and cable length must be specified in the contract. If not specified, the supply shall be 25 meters for the cable and 20 meters for the hose.
2. If the user has other special requirements and instructions, they should be stated in the contract, and our company will design and manufacture them on your behalf.
7. Spare parts supplied
10 safety pieces (stored in the screw hole at the right corner of the collector valve body)
Address: No. 010, Xinglong Road, Huilong Industrial Park, Qidong City
Sales hotline: 0513-83637668
Company fax: 0513-83637098
After-sales service: 0513-83635700
Website: delcan.cn
E-mail:qd3637668@163.com